**************************************************************2025.09.30 VX400 Pro V1.2.0********************************************************************** [Supporting Software] Unico V2.3.0 NovaLCT V5.8.0 [New Features] 1. Support the data interworking between NovaLCT and Unico for screen configuration. 2. Support the NCP and rcfgx file sending via Unico. 3. The USB source supports the input backup settings. 4. Support the function of the dual receiving card backup. 5. Changed the names of the transition effects of the USB media file. 6. Connect the multifunction card and use the remote control to power on or power off the screen. 7. Enable the function of compatible with Mac on the device LCD screen. 8. Support the self-adaptive processing of the input source capacity. 9. Support the device standby mode. 10. Add descriptions of the following functions in the control protocol. (1) Obtain the screen brightness. (2) Obtain the primary and backup modes in the backup relationship. (3) Set the test pattern. (4) Control and obtain the color temperature. (5) Adjust the output color. (6) Set the 3D function. (7) Restart the device. (8) Enable or disable the HDCP function. (9) Obtain the OPT port status. (10) Obtain the OPT working mode. [Improvements] 1. Optimized the source recognition performance with enhanced recognition speed. 2. Optimized the application scenarios of the front panel buttons. (Other non-reused buttons can now function normally on the USB player interface.) 3. Optimized the application scenarios of the backup device. (After a backup relationship is created, you can adjust the screen parameters on the front panel of the backup device without unbinding the backup relationship when the primary device is powered off.) 4. Optimized the prompt message of the IP conflict. 5. Optimized the OPT source stability to resolve the issue of occasional screen blackout in the high-temperature environment when the OPT source is provided by the P10 and P20. [Changes] None [Bug Fixes] 1. Fixed the occasional issue where the device LCD screen displays "Starting..." if failures occur during readback of the receiving card data. 2. Fixed the occasional issue of incorrect monitoring image display when the device is powered off and then powered on. [Notes] 1. If you need to use NovaLCT after configuring the screen in Unico, please read back the screen configuration information on the screen configuration page, and then resend the data. 2. For the name of the USB media file, five characters are not supported, including "[", "]", "{", "}" and "、". 3. When a mosaic source contains a sub-source with the frame rate exceeding 60Hz, the device overload prompt displayed on the device LCD screen and software is incorrect. 4. If the remote control function is enabled when the configured the screen width is less than 1017 pixels, two extra columns of pixels will appear on the right side of the OSD menu interface. To resolve this issue, you can increase the canvas size or screen width to exceed 1017 pixels. 5. After you update the device from V1.0.x to V1.2.0, you need to perform factory reset settings; while the factory reset operation is not required after you update the device from V1.1.2 to V1.2.0. *****************************************2025.09.05 VX400 Pro V1.1.2********************************************************************** [Supporting Software] NovaLCT V5.7.1.CTM7801 [New Features] 1. Support the device update on the Unico web page. [Improvements] None [Changes] 1. Removed the feature to enable low-latency mode by default [Bug Fixes] 1. Fixed the issue where the UI language of Unico web page did not change following the various systems. 2. Fixed the issue where InfoFrame override on the layer editing web page did not take effect. 3. Fixed the issue where the related function of the screen configuration file is missing on the Unico web page. 7. Fixed the issue where the Save button is missing on the Unico web page. 4. Fixed the issue where the embedded audio of an SDI source can be set. 6. Fixed the issue where the screen becomes blurred when three layers are opened on the screen composed of cabinets with the resolution of 256×256 pixels. [Notes] 1. Reset to factory settings when you update the device from versions earlier than V1.1.1 to V1.1.1.. 2. The dynamic text OSD cannot be saved as a backup preset because the text scrolling is not synchronized. 3. If you want to perform related operations on the Unico web page after operating the receiving card in NovaLCT, it is recommended to Click Refresh on the screen configuration page in Unico. *****************************************2025.08.27 VX400 Pro V1.1.1********************************************************************** [Supporting Software] Unico V2.2.0 NovaLCT V5.7.1.CTM7801 [New Features] 1. Supports the remote control function, and the language options of the OSD menu support English and simplified Chinese. 2. Supports NCP file sending in NovaLCT. 3. Enhanced efficiency of calibration coefficient uploading when Ethernet cables are used for calibration 4. Supports display dehumidification in NovaLCT. 5. Enhanced OSD interactions 6. Enable the low latency function by default. [Improvements] 1. Updated the control protocol content. (For details, please refer to the control protocol documentation.) 2. Optimized the speed of layer opening via front panel buttons. 3. Optimized the preset loading performance. 4. Optimized the layer moving performance. 5. Optimized the preset loading via the preset function button. 6. Optimized the program updating speed. 7. Optimized the USB playback function to support more video formats. [Changes] 1. Changed the preset protocol. 2. Adapted to the protocol of the layer thumbnail displayed in the preset thumbnail. [Bug Fixes] 1. Fixed the issue where a custom model is not synchronized to NovaLCT. 2. Fixed the color cast issue when a matrix is used to switch sources. 3. Fixed the occasional issue where setting network mode fails. 4. Fixed the occasional issue of screen blackout when you restart the device and the backup relationship is configured. 5. Fixed the issue of communication timeout when the device is operated in high-temperature environment. 6. Fixed the issue of incorrect screen topology when the cabinet is rotated. 7. Fixed the occasional where Starting is displayed on the device LCD screen. 8. Fixed the issue where white lines are displayed on the screen when the free topology configuration is completed and the incorrect topology of another receiving card is sent. [Notes] 1. Reset to factory settings when you update the device from versions earlier than V1.1.1 to V1.1.1.. 2. The dynamic text OSD cannot be saved as a backup preset because the text scrolling is not synchronized. 3. If you want to perform related operations on the Unico web page after operating the receiving card in NovaLCT, it is recommended to Click Refresh on the screen configuration page in Unico. 4. The low latency function is enabled by default when the device program version is V1.1.1. If the screen configuration does not meet low latency requirements but the low latency switch is turned on, please disable it manually. *****************************************2025.03.05 VX400 Pro V1.0.0********************************************************************** [Supporting Software] NovaLCT V5.7.0.D1.CTM0100 [New Features] 1. Supports device control via NovaLCT. 2. Supports USB playback function. 3. Supports device backup. 4. Supports color temperature and Gamma adjustments for the display. 5. Supports the About Us menu and neutral settings on Unico web page. 6. Supports device authorization via NovaLCT. 7. Supports calibration via NovaLCT. 8. Supports Unico web page control. 9. Supports screen configurations via the device LCD panel. 10. Supports 3D function. 11. Supports central control protocol, including brightness control and preset switching. [Improvements] None [Changes] None [Bug Fixes] None